Aliquippa Non-Destructive Testing Services

Aliquippa Non-Destructive Testing Services

ASME B31.3 in Aliquippa, PA

ASME B31.3 in Aliquippa, PA

The majority of the piping that you see when you pass an Oil Refinery, Chemical Plant, or any other typeprocessing facility is covered under ASME B31.3. Having provided Nondestructive testing services in Delaware City Refinery, Monroe Energy Refinery, Paulsboro Refinery, Advansix Chemical Plant and Chemours Chemical Plants thisspecification is the one used the most by the NDT technicians at Integrity Testlabs. The two most common acceptance criteria for AMSE B31.3 are Normal Fluid Services (NFS) and Severe Cyclic. Integrity Testlabs provides Non Destructive services of RT, UT, MT, PT, VT to cover any needs that may arise.

Certified Welding Inspector (CWT) in Aliquippa, PA

Many jobsites ranging from pipelines, fabrication shops, bridges and structural steel fabricators need or require a Certified Welding Inspector (CWI) to help run their quality program, certify welders, perform visual inspections on fit-ups, root passes and final inspections of completed welds. CWIs come from different backgrounds, some have welding experience only, Some have inspection experience only and some have an engineering degree. All CWIs need to know how to interpret the welding procedure, welding qualification, acceptance criteria for defects, welding machines, and consumables. Integrity Testlabs can provide a CWI for your long- or short-term projects.

Certified Welding Inspector (CWT) in Aliquippa, PA
C-scan, Shearwave and Phased Array

C-scan, Shearwave and Phased Array

Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

ASNT Level II in Aliquippa, PA

The work horse of any company is your Level II NDT technician. Integrity Testlabs is no exception. Our NDE technicians are SNT-TC-1A certified in PT, MT, RT, UTT, UT Shearwave, UT Phased Array. Capable of completing jobs in the field or shop in a timely manner. To become a Level II NDE technician you need to complete so many OJT hours and classroom training. Completion of these hours can take 2-5 years. Integrity Testlabs provides seasoned technicians to complete your job at hand. Oil Refineries, Chemical Plants, Railroad, Fab shops and Shipyards we have an inspector for you.

ASNT Level II in Aliquippa, PA
API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

ACFM; Alternating current field measurement in Aliquippa, PA

ACFM; Alternating current field measurement in Aliquippa, PA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.