Non-Destructive Testing Services in Avoca, PA

Non-Destructive Testing Services in Avoca, PA

API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

Avoca, PA API 580

API 580 was developed by the American Petroleum Institute (API) in 2002. It is primarily adopted in oil and chemical refineries for developing programs to track and maintain inspections in keys areas of the piping or equipment that is affected by the process it contains. API 580 is program will keep workers and communities safe from releases or catastrophic failures. Integrity Testlabs has provided support for API 580 by providing Radiographic inspections and Ultrasonic Thickness inspections on piping, shells of exchangers, towers and drums. Radiography provides an actual imagine of the corrosion that is occurring and UT grids can provide a visual by numbers on where wall loss is happening.

Avoca, PA API 580
ASTM International

ASTM

ASTM International is a globally recognized leader in the development and delivery of voluntary consensus standards. Over 12000 ASTM standards are used around the world to improve product quality, enhance health and safety, strengthen market access and trade, and build consumer confidence. International standards development is driven by the contributions of the members: more than 30,000 of the world’s top technical experts and business professionals representing 140 countries. Working in an open and transparent process and using ASTM’s advanced IT infrastructure, members create the test methods, specifications, classifications, guides and practices that support industries and governments worldwide.

Avoca, PA Visual Testing (VT)

Probably the most important inspection technique and one we are gifted with is visual testing with our eyes. This is a very common, low cost, quick and effective way to inspect welding, equipment, and coatings. Visual testing is the most important tool for a Certified Welding Inspector (CWI), It’s a certification you can acquire through ASNT or with your company by ASNT TC 1A. Defects commonly found using visual inspection is excessive reinforcement, underfill, undercut, porosity, cold lap. If able to access the inside or root of the weld its possible to see lack of fusion, or incomplete penetration.

Avoca, PA Visual Testing (VT)

ASME B31.1 in Avoca, PA

Created in the 1930s as a standard code for power piping. ASME B31.1 is a code that provides minimum requirements for safety and guidance for the design of new piping and the repair, modifications and replacement of existing piping. Covering fuel gas and oil systems as well as central and district heating, water and steam systems. ASME B31.1 covers water and steam piping found in all power generation plants throughout the United States. Integrity Testlabs can provided technicians on your next project or outage that have vast experience and knowledge of ASME B31.1 acceptance criteria.

ASME B31.1 in Avoca, PA
Avoca, PA Industrial Radiography

Avoca, PA Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.