Non-Destructive Testing Services in Boston, VA

Non-Destructive Testing Services in Boston, VA

ASME Sec VIII; ASME Boiler & Pressure Vessel Code (BPVC)

ASME Sec VIII; ASME Boiler & Pressure Vessel Code (BPVC)

Section VIII of ASME is the code that covers the design, manufacturing, inspection and testing of pressure vessels that exceed 15 psig. This code book provides specific requirements on welding and forging, mandatory and nonmandatory appendices detailing supplementary design criteria. Manufacturing companies must be certified by AMSE. Integrity Testlabs can provide all Non-destructive need to meet or exceed the requirements of ASME Sec VIII ASTM; American Society Testing and Materials.

ANST Level I and Assistants

ANST Level I and Assistants

Becoming certified or learning about Nondestructive testing can be achieved in two ways. Enrolling in a school that provides a certificate or degree or getting hired on with a company with no knowledge of the industry and learning on the job. Typically 40hrs of radiation safety is the first step/certificate that is needed to get started. Once the Assistant has had some time in the industry the company will provide them with classroom training either in house, computer based or sending them to a course provided by a known 3rd party. When the Assistants meets the required OJT hours and classroom time. They will test with the company they are with by completing a specific, general and practical exams. When this is completed, they are now a Level II technician.

Boston, VA API 580

API 580 was developed by the American Petroleum Institute (API) in 2002. It is primarily adopted in oil and chemical refineries for developing programs to track and maintain inspections in keys areas of the piping or equipment that is affected by the process it contains. API 580 is program will keep workers and communities safe from releases or catastrophic failures. Integrity Testlabs has provided support for API 580 by providing Radiographic inspections and Ultrasonic Thickness inspections on piping, shells of exchangers, towers and drums. Radiography provides an actual imagine of the corrosion that is occurring and UT grids can provide a visual by numbers on where wall loss is happening.

Boston, VA API 580

Ground Penetrating Radar in Boston, VA

Integrity Testlabs can provide a safe, cost effective and nondestructive means to scan concrete slabs or structures prior to drilling, cutting or coring. Prior to doing destructive work to concrete, inspecting the interior for possible post tension cables, electrical lines, pipes and rebar can save you time and money. ITL trained technicians that can provide this service and mark out where these items exist inside the concrete. This risk mitigation technique will allow you to cut, core or drill with a peace of mind.

Ground Penetrating Radar in Boston, VA
Boston, VA Radiation Safety Officer (RSO)

Boston, VA Radiation Safety Officer (RSO)

Any Company providing Radiography services will need a Radiation Safety Officer (RSO). The RSO will oversee all codes and regulations regarding the storage and use of category 2 material. The RSO will oversee all daily activities by the crews. Making sure they are performing the work safely and using all safety devices. Ir-192 is what Integrity Testlabs uses the most to perform radiography. We use QSA Global as our service provider of source and equipment. The D/S-880 has been a trusted workhorse for ITL techs out in the field. ITL is still using source projectors that are over 20 years old.

ACFM; Alternating current field measurement in Boston, VA

ACFM; Alternating current field measurement in Boston, VA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.