Brandermill Non-Destructive Testing Services

Brandermill Non-Destructive Testing Services

ACFM; Alternating current field measurement in Brandermill, VA

ACFM; Alternating current field measurement in Brandermill, VA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

Brandermill, VA Non-Destructive Visual Testing (VT)

Brandermill, VA ASNT Level III

Brandermill, VA ASNT Level III

Integrity Testlabs has in house ASNT Certified Level III to train and keep our technicians updated on the latest revisions to code and equipment upgrades as well as training. Our Level IIII keeps our procedures updated and is current with the latest ASME, API, ABS Revisions. We also offer 3rd party certifications for your employees or if your company needs a reviewer, monitor or to evaluate your program, procedures or film let Integrity Testlabs help you.

ANST Level I and Assistants

ANST Level I and Assistants

Becoming certified or learning about Nondestructive testing can be achieved in two ways. Enrolling in a school that provides a certificate or degree or getting hired on with a company with no knowledge of the industry and learning on the job. Typically 40hrs of radiation safety is the first step/certificate that is needed to get started. Once the Assistant has had some time in the industry the company will provide them with classroom training either in house, computer based or sending them to a course provided by a known 3rd party. When the Assistants meets the required OJT hours and classroom time. They will test with the company they are with by completing a specific, general and practical exams. When this is completed, they are now a Level II technician.

Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.