
Breesport Non-Destructive Testing Services

API 1169
The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

C-scan, Shearwave and Phased Array
Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

Turnaround or Outage Support
Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.
Certified Welding Inspector (CWT) in Breesport, NY
Many jobsites ranging from pipelines, fabrication shops, bridges and structural steel fabricators need or require a Certified Welding Inspector (CWI) to help run their quality program, certify welders, perform visual inspections on fit-ups, root passes and final inspections of completed welds. CWIs come from different backgrounds, some have welding experience only, Some have inspection experience only and some have an engineering degree. All CWIs need to know how to interpret the welding procedure, welding qualification, acceptance criteria for defects, welding machines, and consumables. Integrity Testlabs can provide a CWI for your long- or short-term projects.

ASME B31.1 in Breesport, NY
Created in the 1930s as a standard code for power piping. ASME B31.1 is a code that provides minimum requirements for safety and guidance for the design of new piping and the repair, modifications and replacement of existing piping. Covering fuel gas and oil systems as well as central and district heating, water and steam systems. ASME B31.1 covers water and steam piping found in all power generation plants throughout the United States. Integrity Testlabs can provided technicians on your next project or outage that have vast experience and knowledge of ASME B31.1 acceptance criteria.

Breesport, NY API 650/ API 653
This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.
