Non-Destructive Testing Services in Bull Run, VA

Non-Destructive Testing Services in Bull Run, VA

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

Traditional Film, Computed Radiography and Digital radiography in Bull Run, VA

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Bull Run, VA

Bull Run, VA Magnetic Particle Testing (MT)

If you’re looking for a very mobile, reliable and cost-effective method at finding surface and subsurface discontinuities. MT testing is the way to go on your ferrous material. When the magnetic field is disrupted by a break in the north and south poles the fine iron particles are attracted to the break in the magnetic field. Dry or wet inspections can be very useful with dry being the advantage when parts are to hot to use the wet method. ITL has many certified MT technicians to perform inspections on your welds or parts.

Bull Run, VA Magnetic Particle Testing (MT)
C-scan, Shearwave and Phased Array

C-scan, Shearwave and Phased Array

Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

Bull Run, VA API 650/ API 653

This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.

Bull Run, VA API 650/ API 653

Bull Run, VA Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

Bull Run, VA Ultrasonics