Non-Destructive Testing Services in Central Falls, RI

C-scan, Shearwave and Phased Array
Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.
Central Falls, RI API 650/ API 653
This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.


Eddy Current
Eddy Current uses electromagnetic induction with alternating currents passed through a coil. The coil produces alternating magnetic field. Used extensively in the aircraft industry and manufacturing industry to look for surface and subsurface defects. Also used in the Nuclear and Petro chemical industry on heat exchanger tubing. When the surface is properly cleaned Eddy Current (ET) can be a fast and very effective Nondestructive inspection.

Central Falls, RI Radiation Safety Officer (RSO)
Any Company providing Radiography services will need a Radiation Safety Officer (RSO). The RSO will oversee all codes and regulations regarding the storage and use of category 2 material. The RSO will oversee all daily activities by the crews. Making sure they are performing the work safely and using all safety devices. Ir-192 is what Integrity Testlabs uses the most to perform radiography. We use QSA Global as our service provider of source and equipment. The D/S-880 has been a trusted workhorse for ITL techs out in the field. ITL is still using source projectors that are over 20 years old.
Central Falls, RI Visual Testing (VT)
Probably the most important inspection technique and one we are gifted with is visual testing with our eyes. This is a very common, low cost, quick and effective way to inspect welding, equipment, and coatings. Visual testing is the most important tool for a Certified Welding Inspector (CWI), It’s a certification you can acquire through ASNT or with your company by ASNT TC 1A. Defects commonly found using visual inspection is excessive reinforcement, underfill, undercut, porosity, cold lap. If able to access the inside or root of the weld its possible to see lack of fusion, or incomplete penetration.


ANST Level I and Assistants
Becoming certified or learning about Nondestructive testing can be achieved in two ways. Enrolling in a school that provides a certificate or degree or getting hired on with a company with no knowledge of the industry and learning on the job. Typically 40hrs of radiation safety is the first step/certificate that is needed to get started. Once the Assistant has had some time in the industry the company will provide them with classroom training either in house, computer based or sending them to a course provided by a known 3rd party. When the Assistants meets the required OJT hours and classroom time. They will test with the company they are with by completing a specific, general and practical exams. When this is completed, they are now a Level II technician.