Charlton Non-Destructive Testing Services

Charlton Non-Destructive Testing Services

Charlton, MD API 650/ API 653

This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.

Charlton, MD API 650/ API 653

ASNT Level II in Charlton, MD

The work horse of any company is your Level II NDT technician. Integrity Testlabs is no exception. Our NDE technicians are SNT-TC-1A certified in PT, MT, RT, UTT, UT Shearwave, UT Phased Array. Capable of completing jobs in the field or shop in a timely manner. To become a Level II NDE technician you need to complete so many OJT hours and classroom training. Completion of these hours can take 2-5 years. Integrity Testlabs provides seasoned technicians to complete your job at hand. Oil Refineries, Chemical Plants, Railroad, Fab shops and Shipyards we have an inspector for you.

ASNT Level II in Charlton, MD

Charlton Drone Inspection

Using drones is quickly becoming a common inspection method. The biggest attraction is offering a safe way to inspect confined spaces and inspected areas high in the air. With todays advanced cameras they are capable of doing a very good visual inspection. Some drones offer infrared capabilities. This allows the operator to look for hot or cold spots on equipment, structures or solar panels. Smaller drones make for good options to investigate or inspect confined spaces. Larger drones are capable of using or deploying Ultrasonics to perform thickness readings on hard to reach places. To use a drone for commercial purposes the operator must have a FAA license.

Charlton Drone Inspection
ACFM; Alternating current field measurement in Charlton, MD

ACFM; Alternating current field measurement in Charlton, MD

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

Eddy Current

Eddy Current

Eddy Current uses electromagnetic induction with alternating currents passed through a coil. The coil produces alternating magnetic field. Used extensively in the aircraft industry and manufacturing industry to look for surface and subsurface defects. Also used in the Nuclear and Petro chemical industry on heat exchanger tubing. When the surface is properly cleaned Eddy Current (ET) can be a fast and very effective Nondestructive inspection.