Non-Destructive Testing Services in Cheswold, DE

Non-Destructive Testing Services in Cheswold, DE

API 510 Inspector in Cheswold, DE

API 510 Inspector in Cheswold, DE

This is an individual certification that is achieved through API testing program that test individuals on their knowledge of inspections, maintenance, repairs and alteration of pressure vessels. This certificate is recognized worldwide. Most individuals have many years of inspection experience of the internals of a pressure vessel, performing Ultrasonic Thickness readings, Visual Inspections and other various NDT methods. Having an understanding of how the operations of the facility work also helps you understand where failures might occur in the different variety of vessels. Integrity Testlabs has API 510 in house and contractors that can help your company keep up with planned and unplanned maintenance and help start or maintain corrosion programs.

Cheswold, DE ASNT Level III

Cheswold, DE ASNT Level III

Integrity Testlabs has in house ASNT Certified Level III to train and keep our technicians updated on the latest revisions to code and equipment upgrades as well as training. Our Level IIII keeps our procedures updated and is current with the latest ASME, API, ABS Revisions. We also offer 3rd party certifications for your employees or if your company needs a reviewer, monitor or to evaluate your program, procedures or film let Integrity Testlabs help you.

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

Cheswold, DE Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

Cheswold, DE Ultrasonics
Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

ACFM; Alternating current field measurement in Cheswold, DE

ACFM; Alternating current field measurement in Cheswold, DE

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.