Delevan Non-Destructive Testing Services

Delevan Non-Destructive Testing Services

Delevan, NY API 650/ API 653

This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.

Delevan, NY API 650/ API 653
Delevan, NY ASNT Level III

Delevan, NY ASNT Level III

Integrity Testlabs has in house ASNT Certified Level III to train and keep our technicians updated on the latest revisions to code and equipment upgrades as well as training. Our Level IIII keeps our procedures updated and is current with the latest ASME, API, ABS Revisions. We also offer 3rd party certifications for your employees or if your company needs a reviewer, monitor or to evaluate your program, procedures or film let Integrity Testlabs help you.

ACFM; Alternating current field measurement in Delevan, NY

ACFM; Alternating current field measurement in Delevan, NY

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

Delevan, NY API 580

API 580 was developed by the American Petroleum Institute (API) in 2002. It is primarily adopted in oil and chemical refineries for developing programs to track and maintain inspections in keys areas of the piping or equipment that is affected by the process it contains. API 580 is program will keep workers and communities safe from releases or catastrophic failures. Integrity Testlabs has provided support for API 580 by providing Radiographic inspections and Ultrasonic Thickness inspections on piping, shells of exchangers, towers and drums. Radiography provides an actual imagine of the corrosion that is occurring and UT grids can provide a visual by numbers on where wall loss is happening.

Delevan, NY API 580
C-scan, Shearwave and Phased Array

C-scan, Shearwave and Phased Array

Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

Traditional Film, Computed Radiography and Digital radiography in Delevan, NY

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Delevan, NY