District Heights Non-Destructive Testing Services

District Heights Non-Destructive Testing Services

Non-Destructive Welding Testing in District Heights, MD

Integrity Test Labs is the leading provider of NDT welding inspection services in District Heights, MD. We check the integrity of your metal by employing a variety of testing methods including visual methodology, radiographic inspection, real-time x-ray, and more. Our NDT welding inspection company has served the District Heights area for over 20 years, helping to protect the assets of local industries. Customer satisfaction is our top priority and we are dedicated to maintaining long-term relationships with clients based on consistently high-quality service. With the assistance of our NDT professionals, you can guarantee the integrity of your work. Contact us today for a consultation with one of our NDT inspectors in District Heights, MD.

District Heights, MD American Welding Society (AWS)
API 510 Inspector in District Heights, MD

API 510 Inspector in District Heights, MD

This is an individual certification that is achieved through API testing program that test individuals on their knowledge of inspections, maintenance, repairs and alteration of pressure vessels. This certificate is recognized worldwide. Most individuals have many years of inspection experience of the internals of a pressure vessel, performing Ultrasonic Thickness readings, Visual Inspections and other various NDT methods. Having an understanding of how the operations of the facility work also helps you understand where failures might occur in the different variety of vessels. Integrity Testlabs has API 510 in house and contractors that can help your company keep up with planned and unplanned maintenance and help start or maintain corrosion programs.

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

District Heights Drone Inspection

Using drones is quickly becoming a common inspection method. The biggest attraction is offering a safe way to inspect confined spaces and inspected areas high in the air. With todays advanced cameras they are capable of doing a very good visual inspection. Some drones offer infrared capabilities. This allows the operator to look for hot or cold spots on equipment, structures or solar panels. Smaller drones make for good options to investigate or inspect confined spaces. Larger drones are capable of using or deploying Ultrasonics to perform thickness readings on hard to reach places. To use a drone for commercial purposes the operator must have a FAA license.

District Heights Drone Inspection
API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

Traditional Film, Computed Radiography and Digital radiography in District Heights, MD

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in District Heights, MD