Halfway House Non-Destructive Testing Services

Halfway House Non-Destructive Testing Services

Halfway House, PA Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

Halfway House, PA Ultrasonics

Ground Penetrating Radar in Halfway House, PA

Integrity Testlabs can provide a safe, cost effective and nondestructive means to scan concrete slabs or structures prior to drilling, cutting or coring. Prior to doing destructive work to concrete, inspecting the interior for possible post tension cables, electrical lines, pipes and rebar can save you time and money. ITL trained technicians that can provide this service and mark out where these items exist inside the concrete. This risk mitigation technique will allow you to cut, core or drill with a peace of mind.

Ground Penetrating Radar in Halfway House, PA

Traditional Film, Computed Radiography and Digital radiography in Halfway House, PA

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Halfway House, PA
ASTM International

NDT Inspections in Halfway House, PA

When checking for flaws in your structures and systems, it is important to find a reliable inspector who can guarantee accurate results. Integrity Test Labs offers professional, non-destructive testing in Halfway House, PA. With a range of different NDT services, we can provide precise readings personalized to your specific needs. Whether you require visual testing, radiography testing, ultrasound testing, penetrant testing, or magnetic particle testing, our company can provide you with comprehensive inspections to detect any anomalies. If you are currently designing new systems, we can also provide hardness testing to measure the resistance and durability of your materials. This service is essential to determining whether or not your metal can withstand certain conditions.

Eddy Current

Eddy Current

Eddy Current uses electromagnetic induction with alternating currents passed through a coil. The coil produces alternating magnetic field. Used extensively in the aircraft industry and manufacturing industry to look for surface and subsurface defects. Also used in the Nuclear and Petro chemical industry on heat exchanger tubing. When the surface is properly cleaned Eddy Current (ET) can be a fast and very effective Nondestructive inspection.

Halfway House, PA API 650/ API 653

This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.

Halfway House, PA API 650/ API 653