Non-Destructive Testing Services in Hamorton, PA

C-scan, Shearwave and Phased Array
Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

API 1169
The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

API 570
The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.
Certified Welding Inspector (CWT) in Hamorton, PA
Many jobsites ranging from pipelines, fabrication shops, bridges and structural steel fabricators need or require a Certified Welding Inspector (CWI) to help run their quality program, certify welders, perform visual inspections on fit-ups, root passes and final inspections of completed welds. CWIs come from different backgrounds, some have welding experience only, Some have inspection experience only and some have an engineering degree. All CWIs need to know how to interpret the welding procedure, welding qualification, acceptance criteria for defects, welding machines, and consumables. Integrity Testlabs can provide a CWI for your long- or short-term projects.

Hamorton, PA Visual Testing (VT)
Probably the most important inspection technique and one we are gifted with is visual testing with our eyes. This is a very common, low cost, quick and effective way to inspect welding, equipment, and coatings. Visual testing is the most important tool for a Certified Welding Inspector (CWI), It’s a certification you can acquire through ASNT or with your company by ASNT TC 1A. Defects commonly found using visual inspection is excessive reinforcement, underfill, undercut, porosity, cold lap. If able to access the inside or root of the weld its possible to see lack of fusion, or incomplete penetration.


ACFM; Alternating current field measurement in Hamorton, PA
Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.