Jacksonville Non-Destructive Testing Services

Jacksonville Non-Destructive Testing Services

C-scan, Shearwave and Phased Array

C-scan, Shearwave and Phased Array

Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

Traditional Film, Computed Radiography and Digital radiography in Jacksonville, NY

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Jacksonville, NY

Jacksonville, NY Ultrasonic Inspection

Uses include flaw detection/evaluation, dimensional measurements, and material characterization

Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

Jacksonville, NY Magnetic Particle Testing (MT)

If you’re looking for a very mobile, reliable and cost-effective method at finding surface and subsurface discontinuities. MT testing is the way to go on your ferrous material. When the magnetic field is disrupted by a break in the north and south poles the fine iron particles are attracted to the break in the magnetic field. Dry or wet inspections can be very useful with dry being the advantage when parts are to hot to use the wet method. ITL has many certified MT technicians to perform inspections on your welds or parts.

Jacksonville, NY Magnetic Particle Testing (MT)

Jacksonville, NY API 580

API 580 was developed by the American Petroleum Institute (API) in 2002. It is primarily adopted in oil and chemical refineries for developing programs to track and maintain inspections in keys areas of the piping or equipment that is affected by the process it contains. API 580 is program will keep workers and communities safe from releases or catastrophic failures. Integrity Testlabs has provided support for API 580 by providing Radiographic inspections and Ultrasonic Thickness inspections on piping, shells of exchangers, towers and drums. Radiography provides an actual imagine of the corrosion that is occurring and UT grids can provide a visual by numbers on where wall loss is happening.

Jacksonville, NY API 580