Konterra Non-Destructive Testing Services

Konterra Non-Destructive Testing Services

Konterra, MD Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

Konterra, MD Ultrasonics
API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

Konterra, MD Ultrasonic Inspection

Uses include flaw detection/evaluation, dimensional measurements, and material characterization

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

Konterra, MD Magnetic Particle Testing (MT)

If you’re looking for a very mobile, reliable and cost-effective method at finding surface and subsurface discontinuities. MT testing is the way to go on your ferrous material. When the magnetic field is disrupted by a break in the north and south poles the fine iron particles are attracted to the break in the magnetic field. Dry or wet inspections can be very useful with dry being the advantage when parts are to hot to use the wet method. ITL has many certified MT technicians to perform inspections on your welds or parts.

Konterra, MD Magnetic Particle Testing (MT)
Konterra, MD Radiation Safety Officer (RSO)

Konterra, MD Radiation Safety Officer (RSO)

Any Company providing Radiography services will need a Radiation Safety Officer (RSO). The RSO will oversee all codes and regulations regarding the storage and use of category 2 material. The RSO will oversee all daily activities by the crews. Making sure they are performing the work safely and using all safety devices. Ir-192 is what Integrity Testlabs uses the most to perform radiography. We use QSA Global as our service provider of source and equipment. The D/S-880 has been a trusted workhorse for ITL techs out in the field. ITL is still using source projectors that are over 20 years old.