Non-Destructive Testing Services in New Tripoli, PA

Non-Destructive Testing Services in New Tripoli, PA

ANST Level I and Assistants

ANST Level I and Assistants

Becoming certified or learning about Nondestructive testing can be achieved in two ways. Enrolling in a school that provides a certificate or degree or getting hired on with a company with no knowledge of the industry and learning on the job. Typically 40hrs of radiation safety is the first step/certificate that is needed to get started. Once the Assistant has had some time in the industry the company will provide them with classroom training either in house, computer based or sending them to a course provided by a known 3rd party. When the Assistants meets the required OJT hours and classroom time. They will test with the company they are with by completing a specific, general and practical exams. When this is completed, they are now a Level II technician.

New Tripoli, PA Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

New Tripoli, PA Ultrasonics

Traditional Film, Computed Radiography and Digital radiography in New Tripoli, PA

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in New Tripoli, PA
API 510 Inspector in New Tripoli, PA

API 510 Inspector in New Tripoli, PA

This is an individual certification that is achieved through API testing program that test individuals on their knowledge of inspections, maintenance, repairs and alteration of pressure vessels. This certificate is recognized worldwide. Most individuals have many years of inspection experience of the internals of a pressure vessel, performing Ultrasonic Thickness readings, Visual Inspections and other various NDT methods. Having an understanding of how the operations of the facility work also helps you understand where failures might occur in the different variety of vessels. Integrity Testlabs has API 510 in house and contractors that can help your company keep up with planned and unplanned maintenance and help start or maintain corrosion programs.

ACFM; Alternating current field measurement in New Tripoli, PA

ACFM; Alternating current field measurement in New Tripoli, PA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

New Tripoli, PA Magnetic Particle Testing (MT)

If you’re looking for a very mobile, reliable and cost-effective method at finding surface and subsurface discontinuities. MT testing is the way to go on your ferrous material. When the magnetic field is disrupted by a break in the north and south poles the fine iron particles are attracted to the break in the magnetic field. Dry or wet inspections can be very useful with dry being the advantage when parts are to hot to use the wet method. ITL has many certified MT technicians to perform inspections on your welds or parts.

New Tripoli, PA Magnetic Particle Testing (MT)