Penn Lake Park Non-Destructive Testing Services

Penn Lake Park Non-Destructive Testing Services

Penn Lake Park, PA Industrial Radiography

Penn Lake Park, PA Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.

Penn Lake Park, PA API 650/ API 653

This is a worldwide recognized individual certification achieved through the American Petroleum Institute (API) testing program. Many individuals that hold this certifications are formal inspectors or welders. API 650 is the specification that deals with new construction of oil tanks. API 653 deals with the inspection, maintenance, repairs and alterations of storage tanks. This certification is highly sought after due to the volume of storage tanks located all over the United States holding petroleum products. These tanks require an external inspection every 5 years and an internal inspection every 10 years. Integrity Testlabs has performed many storage tank inspections. Radiographic inspections (RT) on the welding, Wet Fluorescent Magnetic Particle inspection on the floor plates and annular ring weld. Also Providing AUT scans, UT Thickness readings on the shell and UT crawler inspections on the outside of the tank.

Penn Lake Park, PA API 650/ API 653
ACFM; Alternating current field measurement in Penn Lake Park, PA

ACFM; Alternating current field measurement in Penn Lake Park, PA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

API 510 Inspector in Penn Lake Park, PA

API 510 Inspector in Penn Lake Park, PA

This is an individual certification that is achieved through API testing program that test individuals on their knowledge of inspections, maintenance, repairs and alteration of pressure vessels. This certificate is recognized worldwide. Most individuals have many years of inspection experience of the internals of a pressure vessel, performing Ultrasonic Thickness readings, Visual Inspections and other various NDT methods. Having an understanding of how the operations of the facility work also helps you understand where failures might occur in the different variety of vessels. Integrity Testlabs has API 510 in house and contractors that can help your company keep up with planned and unplanned maintenance and help start or maintain corrosion programs.

ANST Level I and Assistants

ANST Level I and Assistants

Becoming certified or learning about Nondestructive testing can be achieved in two ways. Enrolling in a school that provides a certificate or degree or getting hired on with a company with no knowledge of the industry and learning on the job. Typically 40hrs of radiation safety is the first step/certificate that is needed to get started. Once the Assistant has had some time in the industry the company will provide them with classroom training either in house, computer based or sending them to a course provided by a known 3rd party. When the Assistants meets the required OJT hours and classroom time. They will test with the company they are with by completing a specific, general and practical exams. When this is completed, they are now a Level II technician.