Non-Destructive Testing Services in Roanoke, VA

Non-Destructive Testing Services in Roanoke, VA

Roanoke, VA ASNT Level III

Roanoke, VA ASNT Level III

Integrity Testlabs has in house ASNT Certified Level III to train and keep our technicians updated on the latest revisions to code and equipment upgrades as well as training. Our Level IIII keeps our procedures updated and is current with the latest ASME, API, ABS Revisions. We also offer 3rd party certifications for your employees or if your company needs a reviewer, monitor or to evaluate your program, procedures or film let Integrity Testlabs help you.

Roanoke, VA Industrial Radiography

Roanoke, VA Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.

Roanoke, VA API 1104

Roanoke, VA API 1104

The American Petroleum Institute (API) is one of the oldest and most successful programs that started over 100 years ago. Maintaining over 500 standards in the oil and gas field. One of those standards that Integrity Testlabs has experience in is API 1104. This specification covers Welding Procedure specifications to NonDestructive Testing (NDT) acceptance criteria for the welding of pipelines and related facilities. Integrity Testlabs has the capability and knowledge to inspect all welds requiring NonDestructive Testing Services. We can provide Certified Welding Inspection (CWI), Radiography (RT), Ultrasonic Testing (UT), Magnetic Particle Testing (MT), and Penetrant Testing (PT) needs.

ACFM; Alternating current field measurement in Roanoke, VA

ACFM; Alternating current field measurement in Roanoke, VA

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

Roanoke, VA American Welding Society (AWS)

Founded in 1919 the American Welding Society (AWS) is a nonprofit organization that is made up of members and panels of members. They are yearly contributing to advancing the science, technology, and application of welding and allied joining and cutting processes worldwide, including brazing, soldering and thermal spraying. Many well-known certifications come from AWS. The CWI or Certified Welding Inspector is one of them. Integrity Testlabs has in house and contract CWI qualified workers to meet the need of any project.

Roanoke, VA American Welding Society (AWS)

Traditional Film, Computed Radiography and Digital radiography in Roanoke, VA

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Roanoke, VA