Non-Destructive Testing Services in Ronkonkoma, NY

Non-Destructive Testing Services in Ronkonkoma, NY

Ronkonkoma, NY Non-Destructive Visual Testing (VT)

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

Ronkonkoma, NY Industrial Radiography

Ronkonkoma, NY Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.

Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

Ronkonkoma, NY ABS Service Provider

American Bureau of shipping is a standard that covers the building, repair and overhauling of vessels ranging from tug boats to container ships. Integrity Testlabs for several years now has been a ABS Service Provider. We are currently one of the only Non-Destructive test companies on the East Coast to have this certification. Integrity Testlabs has provided over 20 years of service to the Philly Ship Yard. We have experience inspecting cargo ships, tankers and Navy vessels that have been built at this facility. We have certified technicians available to handle any RT, UT, MT, PT, Wet Fluorescent Magnetic Particle inspections and Fluorescent Penetrant Inspections needs that arise during your ship building, ship repair, ship maintenance, hull repairs, hull thickness readings, propeller shaft inspection and propeller inspection.

Ronkonkoma, NY ABS Service Provider