Sandy Hook Non-Destructive Testing Services

Sandy Hook Non-Destructive Testing Services

Ground Penetrating Radar in Sandy Hook, MD

Integrity Testlabs can provide a safe, cost effective and nondestructive means to scan concrete slabs or structures prior to drilling, cutting or coring. Prior to doing destructive work to concrete, inspecting the interior for possible post tension cables, electrical lines, pipes and rebar can save you time and money. ITL trained technicians that can provide this service and mark out where these items exist inside the concrete. This risk mitigation technique will allow you to cut, core or drill with a peace of mind.

Ground Penetrating Radar in Sandy Hook, MD

ASNT Level II in Sandy Hook, MD

The work horse of any company is your Level II NDT technician. Integrity Testlabs is no exception. Our NDE technicians are SNT-TC-1A certified in PT, MT, RT, UTT, UT Shearwave, UT Phased Array. Capable of completing jobs in the field or shop in a timely manner. To become a Level II NDE technician you need to complete so many OJT hours and classroom training. Completion of these hours can take 2-5 years. Integrity Testlabs provides seasoned technicians to complete your job at hand. Oil Refineries, Chemical Plants, Railroad, Fab shops and Shipyards we have an inspector for you.

ASNT Level II in Sandy Hook, MD

Sandy Hook, MD Ultrasonics

Using high frequency sound energy to conduct examinations and make measurements. Ultrasonic inspection can be used for flaw detection/evaluation, dimensional measurements, material characterization. The sound energy is introduced and propagates through the material in the form of waves. When there is a discontinuity or crack in the wave path, part of the energy will be reflected. back from the flaw surface. The reflected wave signal is transformed into an electrical signal by the transducer and is displayed on a screen. Advanced Ultrasonics takes many on the job hours and classroom training to become a skilled technician in Ultrasonics. Integrity Testlabs has technicians to cover all your Ultrasonic (UT) needs.

Sandy Hook, MD Ultrasonics

Traditional Film, Computed Radiography and Digital radiography in Sandy Hook, MD

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.

Traditional Film, Computed Radiography and Digital radiography in Sandy Hook, MD
ACFM; Alternating current field measurement in Sandy Hook, MD

ACFM; Alternating current field measurement in Sandy Hook, MD

Integrity Testlabs was one of the first companies to provide this inspection technique in the Northeast. ITL technicians have completed hundreds ACFM inspections on equipment shells in oil refineries in the Northeast. ACFM is a electromagnetic technique used for detecting cracks breaking the surface. Capable of also sizing the defect. ACFM can be used on ferrous and nonferrous metals. ACFM can be fast and effective inspection. It does need the area to be cleaned and electric available to run the ACFM unit. Wet Fluorescent Magnetic Testing (WFMT) can be used as an alternate inspection to confirm the findings of the ACFM.

Sandy Hook, MD API 1104

Sandy Hook, MD API 1104

The American Petroleum Institute (API) is one of the oldest and most successful programs that started over 100 years ago. Maintaining over 500 standards in the oil and gas field. One of those standards that Integrity Testlabs has experience in is API 1104. This specification covers Welding Procedure specifications to NonDestructive Testing (NDT) acceptance criteria for the welding of pipelines and related facilities. Integrity Testlabs has the capability and knowledge to inspect all welds requiring NonDestructive Testing Services. We can provide Certified Welding Inspection (CWI), Radiography (RT), Ultrasonic Testing (UT), Magnetic Particle Testing (MT), and Penetrant Testing (PT) needs.