South Plainfield Non-Destructive Testing Services

South Plainfield Non-Destructive Testing Services

Eddy Current

Eddy Current

Eddy Current uses electromagnetic induction with alternating currents passed through a coil. The coil produces alternating magnetic field. Used extensively in the aircraft industry and manufacturing industry to look for surface and subsurface defects. Also used in the Nuclear and Petro chemical industry on heat exchanger tubing. When the surface is properly cleaned Eddy Current (ET) can be a fast and very effective Nondestructive inspection.

Ground Penetrating Radar in South Plainfield, NJ

Integrity Testlabs can provide a safe, cost effective and nondestructive means to scan concrete slabs or structures prior to drilling, cutting or coring. Prior to doing destructive work to concrete, inspecting the interior for possible post tension cables, electrical lines, pipes and rebar can save you time and money. ITL trained technicians that can provide this service and mark out where these items exist inside the concrete. This risk mitigation technique will allow you to cut, core or drill with a peace of mind.

Ground Penetrating Radar in South Plainfield, NJ
C-scan, Shearwave and Phased Array

C-scan, Shearwave and Phased Array

Automated Corrosion Mapping uses C-scan to do corrosion maps to find flaws on the shells of equipment and piping. AUT can produce very detailed reports for clients to visually see where the corrosion is happening. Shearwave uses high frequency sound waves to identify flaws in the material. Sensitive to surface and subsurface discontinuities it’s a superior inspection tool wen compared to other NDT processes. Phased Array is known for its capabilities to send multiple singles into material to produce highly repeatable results and detailed and accurate cross sections of components. This makes Phased Array a needed to tool to inspect complex shaped parts.

South Plainfield, NJ Industrial Radiography

South Plainfield, NJ Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.

South Plainfield, NJ API 580

API 580 was developed by the American Petroleum Institute (API) in 2002. It is primarily adopted in oil and chemical refineries for developing programs to track and maintain inspections in keys areas of the piping or equipment that is affected by the process it contains. API 580 is program will keep workers and communities safe from releases or catastrophic failures. Integrity Testlabs has provided support for API 580 by providing Radiographic inspections and Ultrasonic Thickness inspections on piping, shells of exchangers, towers and drums. Radiography provides an actual imagine of the corrosion that is occurring and UT grids can provide a visual by numbers on where wall loss is happening.

South Plainfield, NJ API 580

Traditional Film, Computed Radiography and Digital radiography in South Plainfield, NJ

Integrity Testlabs currently utilizes traditional film and computed radiography (CR) film. Traditional film is still loaded under safe lights and developed using a 5-step process in the back our darkrooms. Once dry, the filmed in viewed under a high intensity viewer looking for defects. Traditional film comes in several different sizes and leaves the client with a physical piece of film to view for years to come. Computer Radiography or CR uses plates that are phosphor. When these plates are exposed to radiation, the plates emit a blue light that is interpreted by the film processor and then transmitted into an image and viewed on the computer screen. This process is efficient and plates can be used multiple times, no chemicals are needed to process the film. Digital radiography is newer to the industrial and keeps gaining popularity each year. Limited in film size and mobility. The biggest advantage is shorter x-ray times, less radiation, wire or wireless capabilities, and instant images that are displayed on the computer screen.