Non-Destructive Testing Services in St. Michael, PA

Non-Destructive Testing Services in St. Michael, PA

API 1169

API 1169

The API 1169 is a recommended practice that focuses on the basic requirements needed to do inspection on new onshore pipelines in a safe manor. Broken in to four sections. Inspector responsibilities; making sure the project moves forward in a safe and efficient manor. Inspector in responsible for planning, monitoring, evaluating, and root cause analysis. Personal and General Pipeline Safety; Making sure the requirements of OSHA 29 CFR 1910 and 29 CFR 1926 are met. Environmental and pollution control; Inspectors must know the local, state, and federal permits for Environmental and Pollution control. Basic understanding of the impacts that pipelines have on of water, land and air. General Pipeline Construction; Observing all phases of construction and understanding the difference between compliance and requirements in term on general pipeline construction.

ASME B31.1 in St. Michael, PA

Created in the 1930s as a standard code for power piping. ASME B31.1 is a code that provides minimum requirements for safety and guidance for the design of new piping and the repair, modifications and replacement of existing piping. Covering fuel gas and oil systems as well as central and district heating, water and steam systems. ASME B31.1 covers water and steam piping found in all power generation plants throughout the United States. Integrity Testlabs can provided technicians on your next project or outage that have vast experience and knowledge of ASME B31.1 acceptance criteria.

ASME B31.1 in St. Michael, PA
Eddy Current

Eddy Current

Eddy Current uses electromagnetic induction with alternating currents passed through a coil. The coil produces alternating magnetic field. Used extensively in the aircraft industry and manufacturing industry to look for surface and subsurface defects. Also used in the Nuclear and Petro chemical industry on heat exchanger tubing. When the surface is properly cleaned Eddy Current (ET) can be a fast and very effective Nondestructive inspection.

API 570

API 570

The American Petroleum Institute (API) 570 is a in-service inspection code. Designed for the natural gas, chemical and oil refineries piping systems to prevent failures before they happen. This code covers inspection, rating, repair, and alteration procedures for applicable piping systems. This code applies to metallic and fiberglass-reinforced plastic piping systems, also pressure-relieving devices associated with the systems. Inspectors are tasked with ensuring compliance with this code is followed. Integrity Testlabs has in-house and contract API 570’s to cover any needs that fall under the API 570.

Turnaround or Outage Support

Turnaround or Outage Support

Every year in the Energy and Refinery industry have their planned and or unplanned outages. Typically planned for the spring or fall. The plant will shut down typically for a week to 4 weeks for maintenance. These outages require a number of skilled workers to accomplish the planned work. Typically working around the clock to accomplish this work. These tasks can include replacing equipment, valves, pumps, and piping. They may also overhaul the equipment or overlay the piping or shells to help with corrosion. Integrity Testlabs has the staff to support the needs of the mechanical contractors or the owner operators. We can provide RT, UT, MT, PT and QC/QA support.

St. Michael, PA Industrial Radiography

St. Michael, PA Industrial Radiography

Integrity Testlabs performs industrial radiography (RT) every day. We have crews working or available 24/7/365 days a year to perform RT in DE, PA, NJ, NY, and MD. We have the capability to perform x-rays at your jobsite or in house at our Delaware office. We use Ir-192 gamma radiation in Delta 880 projectors. We have SNT-TC-1A qualified level II radiographers to interpret results for weld quality and thinning on pipe walls. Integrity Testlabs also has a Radiation Safety Officer (RSO) on staff to make sure all safety requirements are followed and we have a Level III on staff to interpret results, provided training and keep procedures updated or create new ones.